Rockwell Disclaimer: The product is used surplus. Urgent Automation is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Urgent Automation is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, Urgent Automation makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Urgent Automation also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Urgent Automation also makes no representations as to your right to install any such firmware on the product. Urgent Automation will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.
Product comes with Urgent Automation's 1-year warranty.
The Eaton RGH316039E is a RG-type breaker with 1600 Amps rating and Electronic ALSIG with maintenance mode trip. It is rated at 80% and 50/60 Hertz. Interrupt ratings for the RGH316039E are: 65 and 125 kAIC at 480 and 240 Volts AC, respectively. The RGH316039E has three poles as well as imperial line and load terminals. Trip unit on the RGH316039E is a Digitrip 310 (electronic ALSIG). The Eaton Arcflash Reduction Maintenance System enables placement of the breaker trip unit in maintenance mode to minimize potential arc flash energy. The potential arc energy is half the level seen with ordinary circuit breakers and fuses and therefore this advanced feature increases worker safety.
The RGH316039E is UL certified and is therefore sealed at the factory after installation of optional accessories. Where local codes permit, field installation of accessories can be performed. Prior to installation, suitability of the RGH316039E for installation requirements should be verified by comparing system requirements with circuit breaker specifications. For the safety of personnel involved in installation and maintenance, it is highly recommended that the RGH316039E is installed and serviced only when the circuit breaker is in the OFF position and associated electrical systems have been de-energized. All local health and safety regulations and procedures should also be followed. Testing and maintenance work should also be carried out while adhering to these precautions. The RGH316039E is available in an RG frame with a 102 pound weight and measurements of 15.5 x 15.5 x 9.75 inches.
Part Number/Catalog No. | RGH316039E |
Product Type | Molded Case Circuit Breaker |
kAIC at 480 Volts AC | 65 |
Amps | 1600 |
Poles | 3 |
Trip Unit | 310+ Electronic LSIG w/ Maintenance Mode |
Terminations | Imperial Tapped Line/Load Conductor |
Max. Rated Current | 2500 A |
Main Conducting Paths | 8 kV |
Endurance | 3,000 Operating Cycles |
Max. Switching Frequency | 60 1/h |
Rated Making Capacity | 20 A |
Rated Operational Voltage | 125/250 V |
Power Consumption at 24 Vac | 612 VA |
Max. Opening Time | 62 ms |
Part Number/Catalog No. | RGH316039E |
Product Type | Molded Case Circuit Breaker |
kAIC at 480 Volts AC | 65 |
Amps | 1600 |
Poles | 3 |
Trip Unit | 310+ Electronic LSIG w/ Maintenance Mode |
Terminations | Imperial Tapped Line/Load Conductor |
Max. Rated Current | 2500 A |
Main Conducting Paths | 8 kV |
Endurance | 3,000 Operating Cycles |
Max. Switching Frequency | 60 1/h |
Rated Making Capacity | 20 A |
Rated Operational Voltage | 125/250 V |
Power Consumption at 24 Vac | 612 VA |
Max. Opening Time | 62 ms |