Rockwell Disclaimer: The product is used surplus. Urgent Automation is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Urgent Automation is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, Urgent Automation makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Urgent Automation also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Urgent Automation also makes no representations as to your right to install any such firmware on the product. Urgent Automation will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.


RGH316035E

Description: The Eaton RGH316035E Molded Case Circuit Breaker operates with 3 Poles and 1600 Amps. The module also has a 310+ Electronic LSG Trip Unit and 8 kV Main Conducting Paths.

Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.

Product comes with Urgent Automation's 1-year warranty.


Description: The Eaton RGH316035E Molded Case Circuit Breaker operates with 3 Poles and 1600 Amps. The module also has a 310+ Electronic LSG Trip Unit and 8 kV Main Conducting Paths.


Rated 4.5 with 12 reviews







About RGH316035E

The Series G RGH316035E module from Eaton is a complete electronic RG type circuit breaker with 1600 Amps current rating. The interrupt capacity specifications for the circuit breaker are 50 kiloamps interrupt capacity at 600 Volts AC, 65 kiloamps interrupt capacity at 480 Volts AC, 70 kiloamps interrupt capacity at 415 Volts AC and 125 kiloamps interrupt capacity at 240 Volts AC. The RGH316035E is an 80% rated device with internal Digitrip 310 RMS Electronic LSG trip unit.  It is a 3-pole device and imperial tapped load / line terminals are part of the RGH316035E. Copper wire (1 to 600 AWG) should be used with copper terminals whereas copper or aluminum wire (500 to 1000 AWG) can be used with aluminum terminals. The rated insulation voltage as per IC 6094702 for main conducting paths is 750 Volts AC. The rated insulation voltage for its auxiliary circuits is 690 Volts AC and the rated impulse withstand voltage for its main conducting paths is 8 kilo Volts. This module’s rated impulse withstand voltage for the auxiliary circuit is 4 kilo Volts.

Only a qualified technician should perform maintenance and installation activities related to the RGH316035E. This breaker must be off during installation and servicing. As a UL certified breaker, the RGH316035E is factory sealed after accessory installation. This also helps in preventing any altering of the breaker calibration. The RGH316035E comes in an RG frame with dimensions of 393.7 x 393.7 x 247.6 millimeters. The approximate weight of the breaker is 42.2 kilograms.


Technical specifications:


Part Number/Catalog No.RGH316035E
Product TypeMolded Case Circuit Breaker
kAIC @ 480VAC65
Amps1600
Poles3
Trip Unit310+ Electronic LSG
TerminationsImperial Tapped Line/Load Conductor
Max. Rated Current2500 A
Main Conducting Paths8 kV
Endurance3,000 Operating Cycles
Max. Switching Frequency60 1/h
Rated Making Capacity20 A
Rated Operational Voltage125/250 V
Power Consumption @ 24 Vac612 VA
Max. Opening Time62 ms
Part Number/Catalog No.RGH316035E
Product TypeMolded Case Circuit Breaker
kAIC @ 480VAC65
Amps1600
Poles3
Trip Unit310+ Electronic LSG
TerminationsImperial Tapped Line/Load Conductor
Max. Rated Current2500 A
Main Conducting Paths8 kV
Endurance3,000 Operating Cycles
Max. Switching Frequency60 1/h
Rated Making Capacity20 A
Rated Operational Voltage125/250 V
Power Consumption @ 24 Vac612 VA
Max. Opening Time62 ms
Common misspellings:
  • RGH3l6035E
  • RGH316o35E