Rockwell Disclaimer: The product is used surplus. Urgent Automation is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Urgent Automation is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, Urgent Automation makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Urgent Automation also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Urgent Automation also makes no representations as to your right to install any such firmware on the product. Urgent Automation will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.
Product comes with Urgent Automation's 1-year warranty.
Eaton Cutler-Hammer is the sole manufacturer of the NGS212033E device. It is a molded case breaker device. With an NG Frame covering the device, it operates with 1200 Amps of current. It belongs to the G Series of Cutler circuit breaker devices. The running voltage has been set at 480 Volts AC. This is a 2-pole device and it ships with the 310+ Electronic LS Trip. Interruptions can be made at various stages as it has different voltage ratings. The NGS212033E comes with a high interrupting capacity of 85 kAIC at 240 Volts AC, and 50 kAIC at 480 Volts AC. The device can be mounted using an imperial mounting device.
The NGS212033E’s optimal running frequency is adjustable and it depends on the type of load that is on the device. It comes with both line and load terminals. The NGS212033E comes with various protective features. It has an Arcflash Reduction maintenance system, an interchangeable trip unit, and a trip indicator. There are various alarms which give alerts for high loads and trips, ground faults, and a zone-selective interlocked feature. The device comes in a compact size. It is 9 inches high, 6 inches long, and 9 inches wide and it weighs 48 pounds. The device has a rating of 80%. The NGS212033E has been certified with the Ul rating. On the front face of the device, a lever is present to toggle the breaker device between the on and off states. A switch is also present that checks the breaker functionality manually. It is used over time to check the tripping function of the device. A 1-year warranty comes with the device that is valid from the date of installation.
Part Number/Catalog No. | NGS212033E |
Product Type | Molded Case Circuit Breaker |
Frame | NG |
Interrupting Capacity | 50 kAIC at 480 Volts AC |
Poles | 2 |
Amps | 120 Amps |
Trip Unit | 310+ Electronic LS |
Terminations | Imperial tapped line/load conductor |
Maximum Rated Current | 1200 Amps |
Main Conducting Paths | 750 Volts AC |
Max. Switching Frequency | 60 1/h |
Rated Making Capacity | 20 Amps |
Maximum Opening Time | 62 milliseconds |
Rated Operational Voltage | 600 Volts AC |
Part Number/Catalog No. | NGS212033E |
Product Type | Molded Case Circuit Breaker |
Frame | NG |
Interrupting Capacity | 50 kAIC at 480 Volts AC |
Poles | 2 |
Amps | 120 Amps |
Trip Unit | 310+ Electronic LS |
Terminations | Imperial tapped line/load conductor |
Maximum Rated Current | 1200 Amps |
Main Conducting Paths | 750 Volts AC |
Max. Switching Frequency | 60 1/h |
Rated Making Capacity | 20 Amps |
Maximum Opening Time | 62 milliseconds |
Rated Operational Voltage | 600 Volts AC |