Rockwell Disclaimer: The product is used surplus. Urgent Automation is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Urgent Automation is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, Urgent Automation makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Urgent Automation also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Urgent Automation also makes no representations as to your right to install any such firmware on the product. Urgent Automation will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.
Product comes with Urgent Automation's 1-year warranty.
The NGH308035E is an Electronic Molded Case Circuit Breaker that is designed and manufactured by the Cutler-Hammer (Eaton Corporation). This circuit breaker is a high-power current protective device rated at 800 Amps and 480 Volts AC, 50 to 60 Hertz. The device is designed to provide accuracy, high quality, and reliability to low voltage circuit-breaker users. The NGH308035E is calibrated at 40 degrees Celsius, but it shows high performance in almost any conditions. It is advised to use this circuit breaker in 0 to 95% relative humidity environment (which should be non-condensing and non-corrosive). Its highly-isolated housing makes this product safe-to-use. In the heart of the system, there is a microprocessor control electronic Digitrip 310 RMS trip unit. It ensures that you can adjust this device to respond to any current provoked failure.
The Eaton Cutler-Hammer NGH308035E has interrupting capacity limited to 100 kAIC at 240 Volts AC, and 65 kAIC at 480 Volts AC voltages. When compared to similar devices on the market, this molded case circuit breaker offers a design that achieves simplified functioning and faster reactions in trip conditions, and it assures compatibility for virtually any application within its current rating. The device has an NG frame size, three poles, and CSA and UL certifications. The Eaton Cutler-Hammer NGH308035E has a total volume of 8.25 x 16.00 x 5.50 inches (210 x 406 x 140 millimeters) and weighs around 22 kilograms (48 pounds). It is generally a maintenance-free device that provides easy replacement of components in the field.
Part Number/Catalog No. | NGH308035E |
Product Type | Molded Case Circuit Breaker |
Frame | NG |
kAIC @ 480 VAC | 65 |
Poles | 3 |
Amps | 80 |
Trip Unit | 310+ Electronic LSG |
Terminations | Imperial tapped line/load conductor |
Max. Rated Current | 1200 A |
Main Conducting Paths | 750 VAC |
Max. Switching Frequency | 60 1/h |
Rated Making Capacity | 20 A |
Max. Opening Time | 62 ms |
Rated Operational Voltage | 600 V |
Part Number/Catalog No. | NGH308035E |
Product Type | Molded Case Circuit Breaker |
Frame | NG |
kAIC @ 480 VAC | 65 |
Poles | 3 |
Amps | 80 |
Trip Unit | 310+ Electronic LSG |
Terminations | Imperial tapped line/load conductor |
Max. Rated Current | 1200 A |
Main Conducting Paths | 750 VAC |
Max. Switching Frequency | 60 1/h |
Rated Making Capacity | 20 A |
Max. Opening Time | 62 ms |
Rated Operational Voltage | 600 V |