Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.
Product comes with Urgent Automation's 1-year warranty.
Rockwell Disclaimer: The product is used surplus. Urgent Automation is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Urgent Automation is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, Urgent Automation makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Urgent Automation also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Urgent Automation also makes no representations as to your right to install any such firmware on the product. Urgent Automation will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.
Product comes with Urgent Automation's 1-year warranty.
The Eaton Cutler-Hammer NGC308032E Molded Case Circuit Breaker is a completely assembled Frame NG circuit breaker with a digital trip unit used for enhanced and accurate overload protection in a variety of applications with high standard and coordination need requirements. It has an electronic trip unit with microprocessor-based RMS current sensing for proper correlation with the thermal characteristics of conductors and equipment, and it has an over-temperature protective feature, which provides added protection in the event that the operating temperature rises above the designated value. The NGC308032E has a current rating of 800 Amps, with a current interrupting limit of 100 kAIC at 480 Volts, and it has a UL-rated line voltage of 600 Volts AC across its terminals. It features the state-of-the-art high-speed blow open contact which keeps the contact from closing in the event of an abnormal circuit condition by using electromechanical force, and it has a hand toggle operating mechanism which indicates the breaker’s position. It has 6 function current settings that are adjustable via a front-mounted switch, and it has a 3-pole wire design with a trip element and trip bar on each pole.
The NGC308032E has a load and line end imperial tapped terminal option made of copper/aluminum conductors, and it is supplied with imperial mounting hardware for easy installation. It features ground fault long-time and short-time pickup setting, and an instantaneous override switch with a rating just below the breaker’s nominal rating for additional protection. The NGC308032E has an average long delay time of 15 seconds, with 0 to 100 milliseconds of short delay time, and it has a thermal memory capable of remembering the timing sequence of recent abnormal circuit conditions, and it is capable of imposing shorter delay timing on subsequent conditions. The NGC308032E has LED status indicators that cannot indicate the cause of faults, and it is shipped with a standard test kit for field testing. It has a standard 40 degrees Celsius calibrated temperature limit with a 100% rating, and it is used within a 0 to 95% non-condensing relative humidity range. It has an approximate mounting weight of 20.4 kilograms (45 pounds), with aggregate dimensions of 209.60 x 406.40 x 139.70 millimeters (8.3 x 16.0 x 5.5 inches) and it is UL, IEC, and CSA certified.
Part Number/Catalog No. | NGC308032E |
Product Type | Molded Case Circuit Breaker |
Frame | NG |
Interrupting Capacity | 100 kAIC at 480 Volts AC |
Poles | 3 |
Amps | 80 Amps |
Trip Unit | 310+ Electronic LSI |
Terminations | Imperial tapped line/load conductor |
Maximum Rated Current | 1200 Amps |
Main Conducting Paths | 750 Volts AC |
Maximum Switching Frequency | 60 1/h |
Rated Making Capacity | 20 Amps |
Maximum Opening Time | 62 milliseconds |
Rated Operational Voltage | 600 Volts AC |
Part Number/Catalog No. | NGC308032E |
Product Type | Molded Case Circuit Breaker |
Frame | NG |
Interrupting Capacity | 100 kAIC at 480 Volts AC |
Poles | 3 |
Amps | 80 Amps |
Trip Unit | 310+ Electronic LSI |
Terminations | Imperial tapped line/load conductor |
Maximum Rated Current | 1200 Amps |
Main Conducting Paths | 750 Volts AC |
Maximum Switching Frequency | 60 1/h |
Rated Making Capacity | 20 Amps |
Maximum Opening Time | 62 milliseconds |
Rated Operational Voltage | 600 Volts AC |