Rockwell Disclaimer: The product is used surplus. Urgent Automation is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Urgent Automation is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, Urgent Automation makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Urgent Automation also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Urgent Automation also makes no representations as to your right to install any such firmware on the product. Urgent Automation will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.
Product comes with Urgent Automation's 1-year warranty.
The Eaton Cutler-Hammer JGE4200FAG Molded Circuit Breaker is a G Series JG Frame circuit breaker that can be used for the protection of appliances and conductors from short-circuits and from current overload. This breaker is designed with a trip unit that consists of a fixed thermal trip element and an adjustable magnetic trip element for instantaneous trip action, and it also has a line and load side terminal options which guarantee easy field wiring. The JGE4200FAG has a 3-pole wiring design with no protection for neutral lines, and like all Frame JG circuit breakers, it is designed for use in heating, air-conditioning, and refrigerating applications. It has a standard AC voltage rating of 600 Volts AC, with a continuous current rating of 200 Amps, and it offers a maximum interrupting current limiting capacity of 18, 25, and 65 KAIC at 600, 480, and 240 Volts AC, respectively.
For easy and simple field installation, the JGE4200FAG features load and line side terminals made of standard copper/aluminum wire conductors, with an average wire size of 25 by 185 millimeters square, and it has metric rated mounting hardware. It also has a fixed thermal trip unit which uses a bimetal strip heated by a load current for thermal trip action, and it also has a user-adjustable magnetic trip unit, which can be field adjustable to up to 10 times the nominal breaker rating. The JGE4200FAG has a handle toggle type of operating mechanism which provides a means of operating the breaker contacts, and which also help indicate the position of the breaker contacts (on, off, or tripped). It has an operating temperature limit of 40 degrees Celsius, and it can be used within a 0 to 95% non-condensing relative humidity range. The JGE4200FAG weighs approximately 8.0 pounds, with total dimensions of 5.3 x 7.0 x 3.6 inches, and it is IEC, UL, and CSA certified.
Part Number/Catalog No. | JGE4200FAG |
Product Type | Molded Case Circuit Breaker |
Frame | JG |
Interrupting Capacity | 25 kAIC at 480 Volts AC |
Pole(s) | 3 |
Amps | 200 Amps |
Trip Unit | Fixed Adjustment |
Terminations | Line/Load Standard |
Rating | 80% |
Maximum Rated Current | 250 Amps |
Auxiliary Circuits | 690 Volts AC |
Main Conducting Paths | 8 kV |
Maximum Switching Frequency | 240 1/h |
Weight | 8 pounds |
Dimensions (W x H x D) | 5.34 x 7 x 3.57 inches |
Part Number/Catalog No. | JGE4200FAG |
Product Type | Molded Case Circuit Breaker |
Frame | JG |
Interrupting Capacity | 25 kAIC at 480 Volts AC |
Pole(s) | 3 |
Amps | 200 Amps |
Trip Unit | Fixed Adjustment |
Terminations | Line/Load Standard |
Rating | 80% |
Maximum Rated Current | 250 Amps |
Auxiliary Circuits | 690 Volts AC |
Main Conducting Paths | 8 kV |
Maximum Switching Frequency | 240 1/h |
Weight | 8 pounds |
Dimensions (W x H x D) | 5.34 x 7 x 3.57 inches |