Rockwell Disclaimer: The product is used surplus. Urgent Automation is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Urgent Automation is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, Urgent Automation makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Urgent Automation also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Urgent Automation also makes no representations as to your right to install any such firmware on the product. Urgent Automation will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.
Product comes with Urgent Automation's 1-year warranty.
The JGE3150FAG is series JG Cutler Hammer circuit breaker from Eaton. The breaker has a molded case, 3 poles, a current rating of 150 Amps, and branch circuit protection. The JGE3150FAG uses a fixed thermal and an adjustable magnetic trip unit. The circuit breaker also has an optional shunt trip and an optional auxiliary switch. The rated operating voltage for the JGE3150FAG is 600 Volts AC and 250 Volts DC. For the terminals, the JGE3150FAG has both line and load terminals. The circuit breaker is 6 pounds in weight, and it measures 6.25 inches in height, 5 inches in width, and 9.25 inches in depth. The JGE3150FAG Eaton circuit breaker has an interrupt rating of 18000 AIC at 600 Volts AC, 25000 AIC at 480 Volts AC, and 65000 AIC at 240 Volts AC. The JGE3150FAG is panel mountable and it provides protection for the neutral terminal.
The circuit breaker has type J-frame. Breakers with this type of frame, including the JGE3150FAG, have a built-in test port to accommodate a test kit. The kit is used to perform a test of the long delay, short delay, and ground fault functions. Additionally, the JGE3150FAG features an LED indicator which is used as a no-trip indicator when using the test port. An additional LED status indicator is also present. The extra indicator flashes green to indicate the operational status of the trip unit. If the LED indicator on the JGE3150FAG blinks, the load current has exceeded 20% of the maximum current rating. The JGE3150FAG meets the UL489 and the IEC EN60898/60947-2 standards.
Part Number/Catalog No. | JGE3150FAG |
Product Type | Molded Case Circuit Breaker |
Frame | JG |
kA @ 480V | 25 |
Pole(s) | 3 |
Amps | 150 |
Trip Unit | Fixed Adjustment |
Terminations | Line/Load Standard |
Rating | 80% |
Max. Rated Current | 250 A |
Auxiliary Circuits | 690 VAC |
Main Conducting Paths | 8 kV |
Max. Switching Frequency | 240 1/h |
Weight | 6 lbs |
Dimensions (W x H x D) | 4.3 x 7 x 3.57 in. |
Part Number/Catalog No. | JGE3150FAG |
Product Type | Molded Case Circuit Breaker |
Frame | JG |
kA @ 480V | 25 |
Pole(s) | 3 |
Amps | 150 |
Trip Unit | Fixed Adjustment |
Terminations | Line/Load Standard |
Rating | 80% |
Max. Rated Current | 250 A |
Auxiliary Circuits | 690 VAC |
Main Conducting Paths | 8 kV |
Max. Switching Frequency | 240 1/h |
Weight | 6 lbs |
Dimensions (W x H x D) | 4.3 x 7 x 3.57 in. |