Rockwell Disclaimer: The product is used surplus. Urgent Automation is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Urgent Automation is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, Urgent Automation makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Urgent Automation also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Urgent Automation also makes no representations as to your right to install any such firmware on the product. Urgent Automation will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.
Product comes with Urgent Automation's 1-year warranty.
The EGH3040FFG is a circuit breaker manufactured by Eaton. The circuit breaker has 3 operating modes which are the on, off, and tripped modes. When the circuit breaker is in the on mode, it operates as normal because it allows the current to pass through it and function normally. In the off mode, which is also known as the reset mode, the EGH3040FFG does not allow any current to pass through. When there is an event where the current that is passing through the device is more than the rated current in the on condition, the switch of the device trips to the tripped position in the center and puts the device in the tripped mode. This prevents any current from flowing and it isolates the input contacts and the output contacts.
For the EGH3040FFG to function normally, the users need to first move the switch to the off position to reset the device, and then they should move it back to the on position to resume normal operation. The maximum rated current of the EGH3040FFG is 40 Amps and the device has 3 poles. The trip type of the device is the fixed thermal and magnetic trip type. There are standard load and line terminations in the circuit breaker. When the users are installing the device, they need to make sure the power to the device is turned off first and that the switch is in the off position. They need to follow the instructions provided by the manufacturer and perform all the necessary functional tests and inspections before the system is used by the users. The users can contact the local distributor or visit the manufacturer's website for any assistance regarding the installation or for any part-specific information.
Part Number/Catalog No. | EGH3040FFG |
Product Type | Molded Case Circuit Breaker |
Frame | EG |
Interrupting Capacity | 65 kAIC at 480 Volts AC |
Pole(s) | 3 |
Amps | 40 Amps |
Trip Unit | Fixed Thermal and Magnetic |
Terminal | Line/load Standard |
Dimensions (WxHxD) | 3 x 5.5 x 2.99 inches |
Weight | 3 pounds |
Part Number/Catalog No. | EGH3040FFG |
Product Type | Molded Case Circuit Breaker |
Frame | EG |
Interrupting Capacity | 65 kAIC at 480 Volts AC |
Pole(s) | 3 |
Amps | 40 Amps |
Trip Unit | Fixed Thermal and Magnetic |
Terminal | Line/load Standard |
Dimensions (WxHxD) | 3 x 5.5 x 2.99 inches |
Weight | 3 pounds |