Rockwell Disclaimer: The product is used surplus. Urgent Automation is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Urgent Automation is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, Urgent Automation makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Urgent Automation also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Urgent Automation also makes no representations as to your right to install any such firmware on the product. Urgent Automation will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.
Product comes with Urgent Automation's 1-year warranty.
The LGH3600FAG is a molded circuit breaker from Eaton. It is from the Series G family of circuit breakers which are manufactured by Eaton. The LGH3600FAG has an L frame and it is suitable for use as per the IEC, CE, UL, or CSA rated applications. It has a maximum current rating of 600 Amps and the device has three poles. The trip unit is a fixed adjustable unit and the terminations of the device have line and load terminals as standard terminals. While installing the device, follow the installation instructions provided by the manufacturer. This is important to ensure the LGH3600FAG is installed correctly without any errors.
When tightening the screws, make sure to set them to the appropriate torque as mentioned in the manual. Applying a greater torque may cause the screws to break. The device should be installed when the power supply is turned OFF and the system is not energized. The trip switch must be switched OFF to ensure that users do not get injured due to shock. Follow the safety procedures and complete all the functional tests as mentioned in the manual before handing over the equipment to the users. It is also advised to verify the proper operation of the device and make sure all the covers are installed before the user starts using the system. The installation of the LGH3600FAG should be done by personnel trained on the system and who have the knowledge to install and replace the device for the safety of the people using the equipment and to prevent any damage to the equipment.
Part Number/Catalog No. | LGH3600FAG |
Product Type | Molded Case Circuit Breaker |
Frame | LG |
kA @ 480V | 65 |
Poles | 3 |
Amps | 600 |
Trip Unit | Fixed Adjustment |
Terminations | Line/Load Standard |
Max. Rated Current | 630 A |
Main Conducting Paths | 750 VAC |
Endurance | 8,000 Operating Cycles |
Max. Switching Frequency | 240 1/h |
Rated Making Capacity | 20 A |
Rated Operational Voltage | 125/250V |
Part Number/Catalog No. | LGH3600FAG |
Product Type | Molded Case Circuit Breaker |
Frame | LG |
kA @ 480V | 65 |
Poles | 3 |
Amps | 600 |
Trip Unit | Fixed Adjustment |
Terminations | Line/Load Standard |
Max. Rated Current | 630 A |
Main Conducting Paths | 750 VAC |
Endurance | 8,000 Operating Cycles |
Max. Switching Frequency | 240 1/h |
Rated Making Capacity | 20 A |
Rated Operational Voltage | 125/250V |