Rockwell Disclaimer: The product is used surplus. Urgent Automation is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Urgent Automation is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, Urgent Automation makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Urgent Automation also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Urgent Automation also makes no representations as to your right to install any such firmware on the product. Urgent Automation will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.
Product comes with Urgent Automation's 1-year warranty.
The Westinghouse/Cutler-Hammer/Eaton KD4200 is a molded case circuit breaker with an interchangeable trip unit. The KD4200 circuit breaker is part of the Series C molded case circuit breakers product line made by the Eaton company. The KD4200 has a K-frame for protection and it is UL and CSA approved. The interrupt ratings for the circuit breaker, as with other K-frame molded case circuit breakers, are capped at 40 kAIC at 415 Volts AC, 10 kAIC at 250 Volts DC, and at 65 kAIC at 240 Volts AC. These interrupt ratings are defined by the International Electrotechnical Commission (IEC 157-1) standards.
The Westinghouse/Cutler-Hammer/Eaton KD4200 circuit breaker has 4 poles and it can be used in electrical circuits that do not exceed an operating current of 200 Amps. Additionally, the protected circuits should not exceed a voltage of 600 Volts AC or 250 Volts DC in alternating current or direct current powered systems/circuits, respectively. The KD4200 circuit breaker does not have a neutral pole and it does not provide neutral protection. The circuit breaker uses a thermal magnetic trip mechanism. The trip unit used by the KD4200 circuit breaker is user-replaceable, provided the breaker was user-assembled. When used to provide protection to 250 Volts DC-powered systems, the KD4200 molded case circuit breaker has a minimum time constant of 8 milliseconds at a current rating of 22 kiloAmps. Note that the KD4200 can be factory-assembled. For the terminals, the circuit breaker has load and line side lug terminals.
Part Number/Catalog No. | KD4200 |
Product Type | Molded Case Circuit Breaker |
Series | C |
Frame | K |
Poles | 4 |
Amps | 200 Amps |
Unit Type | Thermal-Magnetic |
Interrupting Capacity | 65 kA at 240 Volts AC |
Dimensions (W x H x D) | 7.22 x 10.13 x 4.1 inches |
Weight | 11.5 pounds |
Part Number/Catalog No. | KD4200 |
Product Type | Molded Case Circuit Breaker |
Series | C |
Frame | K |
Poles | 4 |
Amps | 200 Amps |
Unit Type | Thermal-Magnetic |
Interrupting Capacity | 65 kA at 240 Volts AC |
Dimensions (W x H x D) | 7.22 x 10.13 x 4.1 inches |
Weight | 11.5 pounds |