Rockwell Disclaimer: The product is used surplus. Urgent Automation is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Urgent Automation is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, Urgent Automation makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Urgent Automation also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Urgent Automation also makes no representations as to your right to install any such firmware on the product. Urgent Automation will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.
Product comes with Urgent Automation's 1-year warranty.
The Cutler-Hammer KD2400F C Series molded case circuit breaker is highly popular and it is made by the Eaton Corporation. Molded case circuit breakers are normally used when there is a chance that the site conditions where the breaker in use will interfere with the normal operation of the thermal overload of the circuit breaker and the machine it is attached to. The KD2400F has protective features for commonplace electrical problems like low temperatures which might prevent thermal protection from tripping, the tripping of the thermal protection unit without an overload due to a high temperature, and also protection from environmental moisture which may affect the operation of thermal protection mechanism by absorbing too much heat.
There are multiple interruption rating for the KD2400F breaker which are 65 kAIC at 240 Volts AC, 25 kAIC at 480 Volts AC, 18 kAIC at 600 Volts AC, 10 kAIC at 250 Volts DC (UL), 65 kAIC at 220 or 240 Volts AC, 35 kAIC at 380, 415, or 440 Volts AC, 18 kAIC at 500 Volts AC, 10 kAIC at 250 Volts DC (IEC). The circuit breaker has a current rating of 60 Amps at a maximum operating temperature of 40 degrees Celsius. The voltage rating for the KD2400F is 600 Volts AC at 50 to 60 Hertz frequency. The terminal type of the circuit breaker is a standard pressure load terminal. The maximum AC voltage rating of the KD2400F is 600 Volts AC. It also has a maximum DC voltage rating of 250 Volts DC. The number of poles featured in the KD2400F is 3.
Part Number/Catalog No. | KD2400F |
Product Type | Frame |
Series | C |
Frame | K |
Poles | 2 |
Amps | 400 Amps |
Unit Type | Thermal-Magnetic |
Interrupting Capacity | 65 kAIC at 240 Volts AC |
Dimensions (W x H x D) | 5.5 x 10.13 x 4.1 inches |
Weight | 7.5 pounds |
Part Number/Catalog No. | KD2400F |
Product Type | Frame |
Series | C |
Frame | K |
Poles | 2 |
Amps | 400 Amps |
Unit Type | Thermal-Magnetic |
Interrupting Capacity | 65 kAIC at 240 Volts AC |
Dimensions (W x H x D) | 5.5 x 10.13 x 4.1 inches |
Weight | 7.5 pounds |