Rockwell Disclaimer: The product is used surplus. Urgent Automation is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Urgent Automation is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, Urgent Automation makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Urgent Automation also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Urgent Automation also makes no representations as to your right to install any such firmware on the product. Urgent Automation will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.
Product comes with Urgent Automation's 1-year warranty.
The GHB2090 circuit breaker is a Series C circuit breakers having a G Frame. These circuit breakers are made to be installed and operated in an environment where the ambient temperature is between 0 and 40 degrees Celsius. Users must make sure that the input current rating of the line conductor should be less than 90 Amps because the circuit breaker has a maximum current rating of 90 Amps. The circuit breaker has 2 poles and it also has a window which indicates the status of the circuit breaker. If the circuit breaker is in the tripped position, it will turn white. The users must perform the necessary functional and inspection tests for the safety of the users and to ensure efficient operation. If users find the circuit breaker is overheating or the contacts are not getting linked and are disconnecting the line and the load terminals during testing, the users must replace the GHB2090.
While performing the GHB2090 installation, it is recommended that the users follow the instructions in the manual and comply with the safety norms to prevent any injury or damage. Also, the users must ensure the power supply on the line terminals is turned off and that there is no voltage present on the system bus to avoid electric shock. While performing the installation of the GHB2090, the switch must be in the off position to prevent an accidental turn-on of the system. Make sure the line and load terminals are connected securely and that there are no exposed wires. The users can contact the manufacturer support team if they need any further assistance.
Part Number/Catalog No. | GHB2090 |
Product Type | Molded Case Circuit Breaker |
Series | C |
Frame | G |
Type | Bolt-On Panelboard |
Pole(s) | 2 |
Trip Amps | 90 |
Dimensions | 4 x 3 x 2.63 inches |
Part Number/Catalog No. | GHB2090 |
Product Type | Molded Case Circuit Breaker |
Series | C |
Frame | G |
Type | Bolt-On Panelboard |
Pole(s) | 2 |
Trip Amps | 90 |
Dimensions | 4 x 3 x 2.63 inches |