Rockwell Disclaimer: The product is used surplus. Urgent Automation is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Urgent Automation is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, Urgent Automation makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Urgent Automation also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Urgent Automation also makes no representations as to your right to install any such firmware on the product. Urgent Automation will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.
Product comes with Urgent Automation's 1-year warranty.
The GHB1090 is a circuit breaker from Eaton. It is from the C Series of Eaton circuit breaker, and the frame identification of the circuit breaker is Frame G. It is UL listed and CSA certified. These circuit breakers are bolt-on panelboard circuit breakers which meet the federal specification W-C-375b. The GHB1090 has a continuous current rating of 90 Amps and it is a single-pole device. It is a thermal-magnetic circuit breaker with non-interchangeable trip units. The GHB1090 is 3 inches wide, 4 inches long, and 2.63 inches deep. The Eaton circuit breakers are designed to be used with the Eaton Power Line 2 type of panelboards and equivalent devices.
To begin the installation, first make sure that the circuit breaker is suited for the application and the voltage limits of the inputs and that the outputs are within the minimum and maximum ratings of the circuit breaker. Before installing the circuit breaker, inspect the GHB1090 for any visible damage. Then make sure the circuit breaker is in the off position before beginning the installation, and make sure that the main power supply of the system is turned off and that voltage is not present. Remove the panelboard front and then remove the line end screw which holds the wire from the bus bar. Position the circuit breaker load-end under the mounting rail. Connect the wire to the line end and secure it with the screw. Once the circuit breaker is mounted, connect the load conductors and the other accessories if there are any. Make sure that the installation is done properly before turning on the system.
Part Number/Catalog No. | GHB1090 |
Product Type | Molded Case Circuit Breaker |
Series | C |
Frame | G |
Type | Bolt-On Panelboard |
Pole(s) | 1 |
Trip Amps | 90 |
Dimensions | 4 x 3 x 2.63 inches |
Part Number/Catalog No. | GHB1090 |
Product Type | Molded Case Circuit Breaker |
Series | C |
Frame | G |
Type | Bolt-On Panelboard |
Pole(s) | 1 |
Trip Amps | 90 |
Dimensions | 4 x 3 x 2.63 inches |