Rockwell Disclaimer: The product is used surplus. Urgent Automation is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Urgent Automation is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, Urgent Automation makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Urgent Automation also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Urgent Automation also makes no representations as to your right to install any such firmware on the product. Urgent Automation will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.
Product comes with Urgent Automation's 1-year warranty.
The HFD3150 devices are manufactured by Eaton Cutler Hammer. It comes from the HFD series C. It comes enclosed in a molded case and mounts in a DIN Rail. The rating for current in this device is 20 Ampere. This three-pole circuit breaker is rated at 250 Volts DC and a 600 Volts AC. Load side terminal is only present in this variant. The operation occurs at a frequency of 50 to 60 Hertz. The thermal and magnetic trip are kept fixed in this variant. It has a factory set operating temperature of 40 degrees.The HFD3150 is 3.38 inches long, 4.13 inches high, and 4.13 inches wide. It weighs 4.25 pounds. This module has 100 Kilo Amperes IC at 240 Volts IC and 65 Kilo Amperes at 480 Volts AC set as the Interruption rating for this variant. It is used for High intensity discharge. The used cases for this device are motor service centers, panelboards, switchboards, and busway systems. It is HACR rated and meets UL/NEMA standards. This module comes along with a lever for powering the device on and off; this lever is on the front face of the module, along with a button which is used to view the tripping property and to observe the operation of the device. The HFD3150 is needed most with an increased amount of electricity demand. It is used to protect the overall circuitry of the system. It keeps on monitoring the system and cuts down the circuit if there is a detection of overload current.
Part Number/Catalog No. | HFD3150 |
Product Type | Molded Case Circuit Breaker |
Series | C |
Frame | F |
Pole(s) | 3 |
Trip Amps | 100 kA @ 240V |
Interrupting Capacity | 4.5 lb |
Weight | Thermal-Magnetic |
Trip Unit | 4.13 x 6 x 3.38 in. |
Part Number/Catalog No. | HFD3150 |
Product Type | Molded Case Circuit Breaker |
Series | C |
Frame | F |
Pole(s) | 3 |
Trip Amps | 100 kA @ 240V |
Interrupting Capacity | 4.5 lb |
Weight | Thermal-Magnetic |