Rockwell Disclaimer: The product is used surplus. Urgent Automation is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Urgent Automation is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, Urgent Automation makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Urgent Automation also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Urgent Automation also makes no representations as to your right to install any such firmware on the product. Urgent Automation will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.


FD4080

Description: The Eaton FD4080 Molded Case Circuit Breaker is in the C Series and has 4 Pole(s). The module has 80 Trip Amps and a Thermal-Magnetic Trip Unit.

Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.

Product comes with Urgent Automation's 1-year warranty.


Description: The Eaton FD4080 Molded Case Circuit Breaker is in the C Series and has 4 Pole(s). The module has 80 Trip Amps and a Thermal-Magnetic Trip Unit.


Rated 4.5 with 20 reviews







About FD4080

The Eaton FD4080 is an 80 Amp rated, F-Frame, complete FD-type circuit breaker. The FD4080 has four poles. It includes both line and load side terminals which are made from steel. Either copper or aluminum wire should be used for termination on the breaker terminals. The recommended cable size range is between #4 to #1/0 AWG. Use of an appropriate joint compound is recommended with aluminum conductors to prevent terminal overheating which can lead to breaker damage and spurious tripping. The FD4080 uses a non-interchangeable magnetic/thermal trip management module. The FD4080 can be used for reverse feed applications and is also HACR rated. The current rating for the FD4080 is 80 Amps. The voltage rating for the FD4080 is around 600 Volts AC or 250 Volts DC. At 250 Volts DC, the FD4080 is rated at 10 kiloamps interrupt capacity. At 480 Volts DC the FD4080 is rated at 35 kiloamps interrupt capacity and at 600 Volts AC it is rated at 18 kiloamps interrupt capacity.

During maintenance and installation, the FD4080 must be in off state to avoid the possibility of injury or death. Installation of any accessories should be done before circuit breaker installation and mounting. Depending on requirements, the FD4080 can be mounted differently. Termination on the breaker can be done once the breaker has been properly mounted. The FD4080 has dimensions of 152.4 by 139.7 by 86.0 millimeters. It has an approximate weight of 2.7 kilograms.


Technical specifications:


Part Number/Catalog No.FD4080
Product TypeMolded Case Circuit Breaker
SeriesC
FrameF
Pole(s)4
Trip Amps35 kA @ 277V
Interrupting Capacity6 lb
WeightThermal-Magnetic
Trip Unit5.5 x 6 x 3.38 in.
Part Number/Catalog No.FD4080
Product TypeMolded Case Circuit Breaker
SeriesC
FrameF
Pole(s)4
Trip Amps35 kA @ 277V
Interrupting Capacity6 lb
WeightThermal-Magnetic
Trip Unit5.5 x 6 x 3.38 in.