Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.
Product comes with Urgent Automation's 1-year warranty.
Rockwell Disclaimer: The product is used surplus. Urgent Automation is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Urgent Automation is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, Urgent Automation makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Urgent Automation also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Urgent Automation also makes no representations as to your right to install any such firmware on the product. Urgent Automation will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.
Product comes with Urgent Automation's 1-year warranty.
The Eaton Cutler-Hammer FD2175 Circuit Breaker is a Series C, Frame F, Molded Case circuit breaker with a non-interchangeable trip unit designed for providing users devices (motor and motor starter) with complete protection against current short-circuit and overloads. This device consists of 3 main components, a non-interchangeable trip unit made of a thermal-magnetic trip element, a trip-free operating mechanism which provides means of operating the circuit breaker contacts, and an extinguishing arc which confine the arc drawn between breaker contacts. The FD2175 has 175 Amps rated continuous current rating, and it is suitable for 500 Volt AC ground and unground system. It has a maximum interrupting rating of 35 KAIC at 480 Volt AC, and it comes with a 2-pole wiring, which can be used in a single-phase system. It is suitable for reverse feed wiring, and it only has load lone terminals, which provides simple and fasting wiring.
The FD2175 is designed to protect conductors and connected devices from overload and short-circuit, and it has a factory designed trip unit, which is closed to any further adjustment from users. The circuit is designed to provide both thermal and magnetic trip action using bimetal metal material and electromagnet connected in series, and with load, and this connection together provided a very cheap and fast acting trip action. It has a rated 40 degree Celsius operating limit and is used in an environment with non-condensing relative humidity range within 0 to 95%. The FD2175 weighs approximately 1.4 Kilogram, with a total mounting dimension of 70 x 152.4 x 86 millimeters, and it is designed to meet, IEC, AS, UL, BS, and SEV standards.
Part Number/Catalog No. | FD2175 |
Product Type | Molded Case Circuit Breaker |
Series | C |
Frame | F |
Pole(s) | 2 |
Trip Amps | 35 kA @ 277V |
Interrupting Capacity | 3 lb |
Weight | Thermal-Magnetic |
Trip Unit | 2.75 x 6 x 3.38 in. |
Part Number/Catalog No. | FD2175 |
Product Type | Molded Case Circuit Breaker |
Series | C |
Frame | F |
Pole(s) | 2 |
Trip Amps | 35 kA @ 277V |
Interrupting Capacity | 3 lb |
Weight | Thermal-Magnetic |
Trip Unit | 2.75 x 6 x 3.38 in. |