Rockwell Disclaimer: The product is used surplus. Urgent Automation is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Urgent Automation is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, Urgent Automation makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Urgent Automation also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Urgent Automation also makes no representations as to your right to install any such firmware on the product. Urgent Automation will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.
Product comes with Urgent Automation's 1-year warranty.
The Westinghouse/Cutler-Hammer EDS2200 is a 2 pole type ED circuit breaker. The breaker only has factory installed load side terminals. Being an Eaton Series C circuit breaker, the EDS2200 can accommodate multiwire connectors which are field installed on the load side terminals. The connectors aid in sharing the load from the circuit breaker to other devices without the need of additional distribution terminal blocks. Multiwire lug kits have insulators, mounting hardware, and tin-plated aluminum connectors. The EDS2200 is designed to be used in protecting single-phase powered circuits. The circuit breaker has a maximum continuous amperage rating of 200 Amps and it is calibrated at 40 degrees Celsius.
The Westinghouse EDS2200 has a non-interchangeable trip type which utilizes a fixed thermal-magnetic trip mechanism that utilizes long-time and instantaneous trip functions. The EDS2200 uses a molded case which is resistant to water and to fungus development. However, the internal components of the breaker are not moisture and fungus-resistant. Therefore, where these qualities are needed, the breaker has to be ordered with special instructions. The EDS2200 has a standard interrupt rating capped at 42 kAIC. For troubleshooting and monitoring, the EDS2200 features a trip arm on its front panel which indicates whether the breaker is actively protecting the circuit (on), whether it has detected a harmful element (tripped), or whether it has completely blocked the power from circulating through the circuit (off). The off and on positions are user induced while the EDS2200 automatically switches to the tripped position each time there is a short circuit.
Part Number/Catalog No. | EDS2200 |
Product Type | Molded Case Circuit Breaker |
Series | C |
Frame | F |
Pole(s) | 2 |
Trip Amps | 42 kAIC at 240 Volts AC |
Interrupting Capacity | 3 pounds |
Weight | Thermal-Magnetic |
Trip Unit | 2.75 x 6 x 3.38 inches |
Part Number/Catalog No. | EDS2200 |
Product Type | Molded Case Circuit Breaker |
Series | C |
Frame | F |
Pole(s) | 2 |
Trip Amps | 42 kAIC at 240 Volts AC |
Interrupting Capacity | 3 pounds |
Weight | Thermal-Magnetic |
Trip Unit | 2.75 x 6 x 3.38 inches |