Rockwell Disclaimer: The product is used surplus. Urgent Automation is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Urgent Automation is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, Urgent Automation makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Urgent Automation also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Urgent Automation also makes no representations as to your right to install any such firmware on the product. Urgent Automation will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.
Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.
Product comes with Urgent Automation's 1-year warranty.
The Eaton EDB2150 is an F-frame Series C circuit breaker with a 150 Amps current rating. F-frame breakers are available for 15 to 225 Amps current ratings and they are available as molded case switches and circuit breakers. The voltage ratings for the EDB2150 are 125 Volts DC or 240 Volts AC (at 50 and 60 Hertz). The Eaton EDB2150 has following interrupt specifications: 22 kiloamps of interrupt capacity at 240 Volts AC and 10 kiloamps of interrupting capacity at 125 Volts DC. The complete EDB2150 has an integrated non-interchangeable thermal-magnetic trip module.
For reliable long-term operation and performance, periodic inspection of the EDB2150 should be performed. Before the inspection, the breaker should be powered off and the work area should be cleared of voltages. Because commercial cleaning agents can cause breaker damage, it should be ensured that a suitable cleaning agent is used which does not adversely affect the circuit breaker. During the inspection, dust, grease, and moisture should be removed from the surface of the breaker. To check the mechanical linkages, the breaker should be switched on and off a few times. To check mechanical tripping, the push-to-trip button should be pressed a few times. The breaker should be checked for cracks and discoloration. Terminals and connectors should be checked for signs of overheating and for looseness. Any field testing of the breaker should be performed as per the NEMA standards. The 2-pole EDB2150 weights approximately 1.3 kilograms. The dimensions of the EDB2150 are 6 inches in height, 2.75 inches in width, and 3.38 inches in depth.
Part Number/Catalog No. | EDB2150 |
Product Type | Molded Case Circuit Breaker |
Series | C |
Frame | F |
Pole(s) | 2 |
Interrupting Capacity | 22 kAIC at 240 Volts AC |
Weight | 3 pounds |
Trip Unit | Thermal-Magnetic |
Dimensions | 2.75 x 6 x 3.38 inches |
Part Number/Catalog No. | EDB2150 |
Product Type | Molded Case Circuit Breaker |
Series | C |
Frame | F |
Pole(s) | 2 |
Interrupting Capacity | 22 kAIC at 240 Volts AC |
Weight | 3 pounds |
Trip Unit | Thermal-Magnetic |
Dimensions | 2.75 x 6 x 3.38 inches |