Rockwell Disclaimer: The product is used surplus. Urgent Automation is not an authorized surplus dealer or affiliate for the Manufacturer of this product. The product may have older date codes or be an older series than that available direct from the factory or authorized dealers. Because Urgent Automation is not an authorized distributor of this product, the Original Manufacturer’s warranty does not apply. While many Allen-Bradley PLC products will have firmware already installed, Urgent Automation makes no representation as to whether a PLC product will or will not have firmware and, if it does have firmware, whether the firmware is the revision level that you need for your application. Urgent Automation also makes no representations as to your ability or right to download or otherwise obtain firmware for the product from Rockwell, its distributors, or any other source. Urgent Automation also makes no representations as to your right to install any such firmware on the product. Urgent Automation will not obtain or supply firmware on your behalf. It is your obligation to comply with the terms of any End-User License Agreement or similar document related to obtaining or installing firmware.


2711-T9C10L1

Description: The 2711-T9A10L1 is a Human Machine Interface (HMI) device which belongs to the Allen-Bradley PanelView Standard Operator Terminals. This terminal is 24VDC powered, has 9-inch colored display, Touch sensitive operator interface, DeviceNet and RS232 printe

Urgent Automation is NOT an authorized distributor for this manufacturer and therefore the manufacturer’s warranty does not apply.

Product comes with Urgent Automation's 1-year warranty.


Description: The 2711-T9A10L1 is a Human Machine Interface (HMI) device which belongs to the Allen-Bradley PanelView Standard Operator Terminals. This terminal is 24VDC powered, has 9-inch colored display, Touch sensitive operator interface, DeviceNet and RS232 printe


Rated 4.6 with 14 reviews







About 2711-T9C10L1

The 2711-T9C10L1 is an Allen-Bradley product for the PanelView Standard Operator Terminals. The terminal connects to a process or machine controller to enable real-time data exchange and visualization of process. This a rugged electronic hardware functions as the Human Machine Interface (HMI) of the process. Operator can control the system through the terminal efficiently and effectively. It is powered by a DC power supply with an input range of 18-32V DC (24V DC nom). With the DeviceNet communication port, operator is provided with extended function of implementing a level of supervision among the machines or processes. This is due to the DeviceNet capability of communicating with multiple partner devices simultaneously. The color active TFT matrix screen provide clear visualization of the graphics and mimic screen. It has a 9-inch screen with resolution of 640 x 480 pixels. The touch screen is made of 384 cells (24 columns x 16 rows) with touch cell size of 26 x 25 pixels. It can be actuated up to 1 million times. The HMI panel can be installed and operated in an environment that is within the operating temperature of 0 to 55° C (32 to 131° F) and Vibration rating 1G up to 2,000 Hz and impulse shock of 15G/30G (operating / non-operating). The HMI’s Heat Dissipation of 39 Watts (133 BTU/HR). Ensure proper grounding is implemented when using the HMI terminal. The operator panel has LED indicators to aid in troubleshooting of the device in case of abnormality. It uses PanelBuilder32 software to develop and download application. This software is also used to configure the terminal’s equally important functions such as security, alarm handling, trends, data logging among others. The memory area of the terminal is allocated for 310 KB for application runtime which is enough to implement a smooth terminal operation without lags and screen freezes. A second memory allocation for 1008KB non-volatile memory stores the application created in the engineering software.

Technical specifications:


Manufacturer: Rockwell Automation
Brand: Allen-Bradley
Part Number: 2711-T9C10L1
Product Family: PanelView Standard Terminals
Product TypeOperator Terminals
Operator Input: Touch
Display Type: Color active matrix TFT
Resolution:640 x 480
Display Area: 171 x 130 mm (6.73 x 5.12 in.)
Touch membrane:384 cells
Application memory: 310 KB application runtime; 1008 KB nonvolatile memory
Touch Actuation:Actuation: 1 million presses
DeviceNet; RS232 (printer)Input Voltage range:
Manufacturer: Rockwell Automation
Brand: Allen-Bradley
Part Number: 2711-T9C10L1
Product Family: PanelView Standard Terminals
Product TypeOperator Terminals
Operator Input: Touch
Display Type: Color active matrix TFT
Resolution:640 x 480
Display Area: 171 x 130 mm (6.73 x 5.12 in.)
Touch membrane:384 cells
Application memory: 310 KB application runtime; 1008 KB nonvolatile memory
Touch Actuation:Actuation: 1 million presses
DeviceNet; RS232 (printer)Input Voltage range: